Grauwasser aus Haushalten/en: Unterschied zwischen den Versionen

Aus INTEWA Wiki
(Die Seite wurde neu angelegt: „The European standard DIN EN 12056-1 defines grey water as faecal-free, less contaminated sewage water, such as that accumulated from showering, bathing or was…“)
(Die Seite wurde neu angelegt: „{| class="wikitable" |- ! !! (German Association for Rainwater Harvesting and Water Utilisation H201) Average (Bandwidth) Showering, tub water + Hand wash basi…“)
Zeile 4: Zeile 4:
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
! !! Grauwasser (fbr H201)  
+
! !! (German Association for Rainwater Harvesting and Water Utilisation H201) Average (Bandwidth)
Durchschnitt (Bandbreite)  
+
Showering, tub water + Hand wash basin
Dusche, Badewanne + Handwaschbecken
 
 
|-
 
|-
| [[Wasserparameter bei der Wasseraufbereitung|CSB]] (mg/l) || 225 (150-400)
+
| Chemical Oxygen Demand [[COD]](mg/l) || 225 (150-400)
 
|-
 
|-
| [[Wasserparameter bei der Wasseraufbereitung|BSB]] (mg/l) BOD biochemical oxygen demand  ||111(85-200)  
+
| Biochemical Oxygen Demand [[BOD]] (mg/l) ||111(85-200)  
 
|-
 
|-
| AFS (mg/l) || 40 (30-70)
+
| [[AFS]](mg/l) || 40 (30-70)
 
|-
 
|-
| Pges (mg/l) || 1,5 (0,5-4)
+
| [[Pges]](mg/l) || 1,5 (0,5-4)
 
|-
 
|-
| Nges (mg/l || 10 (4-16)
+
| [[Nges]](mg/l) || 10 (4-16)
 
|-
 
|-
| [[Wasserparameter bei der Wasseraufbereitung|PH]] || (7,5-8,2)
+
| [[PH]] || (7,5-8,2)
 
|-
 
|-
| Gesamtcoliforme [[Bakterien]] (1/ml) || 10<sup>5</sup> (10-10<sup>5</sup>)
+
| Total Coliform Bacteria (1/ml)|| 10<sup>5</sup> (10-10<sup>5</sup>)
 
|-
 
|-
 
| E.coli ||  
 
| E.coli ||  
 
|-
 
|-
| Fäkalcoliforme [[Bakterien]] (1/ml) || 10<sup>4</sup> (10-10<sup>5</sup>)
+
| Faecal coliform bacteria (1/ml) || 10<sup>4</sup> (10-10<sup>5</sup>)
 
|}
 
|}

Version vom 7. November 2018, 15:57 Uhr

Sprachen:
Deutsch • ‎English


The European standard DIN EN 12056-1 defines grey water as faecal-free, less contaminated sewage water, such as that accumulated from showering, bathing or washing hands, but also from washing machine and for treatment of industrial water or process water. The quality of water can vary greatly, as illustrated in the following survey:

(German Association for Rainwater Harvesting and Water Utilisation H201) Average (Bandwidth)

Showering, tub water + Hand wash basin

Chemical Oxygen Demand COD(mg/l) 225 (150-400)
Biochemical Oxygen Demand BOD (mg/l) 111(85-200)
AFS(mg/l) 40 (30-70)
Pges(mg/l) 1,5 (0,5-4)
Nges(mg/l) 10 (4-16)
PH (7,5-8,2)
Total Coliform Bacteria (1/ml) 105 (10-105)
E.coli
Faecal coliform bacteria (1/ml) 104 (10-105)