- Location: Aachen
- Ared= 100 m²
- Measured rainfall: r15,n=0.2 = 152.6 L/(sha)
- kf = 1*10-4 m/s (medium sand)
- srr = 0.56 (DRAINMAX Tunnel installation according to German Institute for Civil Engineering)
- fz = 1.1